The Minor Works Control System was fully implemented on 31 December 2010 to allow safe, lawful small-scale building works through simplified procedures. It regulates 187 items: 58 Class I items, 68 Class II items and 61 Class III items, categorised by scale, complexity and safety risk. Amendments in 2012 added eight items; amendments effective 1 September 2020 repealed nine, amended 56 and added 70 items.
All three classes do not require prior approval of plans and consent to commencement under section 14(1). Required photographs must show actual conditions before and after the works.
Common Minor Works Relating to Roofs & Glass Houses
Classification depends on dimensions, position and structural conditions, such as cantilevered slabs, additional slab loads or changes to other structural members. Appointed professionals and contractors must meet every applicable requirement. See Aluminium Windows & Doors for window and glazed-wall works, and Glass Balustrades for protective barriers.
30 Designated Exempted Works
The system includes 30 designated exempted works of lower complexity and risk. These do not require prior plan approval, written consent or appointment of an Authorized Person and registered contractor. Roof and outdoor examples include:
- Erection, alteration or removal of canopies not more than 3 metres above ground or roof level.
- Roof mesh fences or metal railings not exceeding 1.1 metres high, without a solid wall at their base.
- Roof posts not exceeding 1.1 metres high, without a solid wall at their base.
- Solid roof walls not exceeding 500 millimetres high.
- Application or replacement of paint- or membrane-based roof waterproofing, without laying or removing tile or floor layers.
- Drying racks not more than 3 metres above ground or roof level.
Designated exemption still requires compliance with the building design and construction standards under the Buildings Ordinance; non-compliant work may remain unauthorised.
Contractor Types & Consent for Common Parts
Registered Minor Works Contractors (Companies) are registered under Types A to H: A alteration and addition, B repair, C signboards, D drainage, E amenity features, F finishes, G demolition and H internal ventilation. Self-employed practitioners may register as individual contractors for Class III items 3.1–3.66. Verify the contractor's classes, types and items cover the work. Works in common parts, such as external walls and the main roof, require consent from all co-owners or the owners' corporation and management company and compliance with the deed of mutual covenant.
The system also includes the Household Minor Works Validation Scheme, Minor Amenity Feature Validation Scheme and Signboard Validation Scheme for qualifying small, low-risk installations constructed before the schemes took effect. Glass houses and large rooftop structures do not fall into these small, low-risk categories.